The Extron IPL EXP 200 is a Control System I/O Expansion Interface designed for easy control system expansion of up to two bidirectional serial ports, one IR/Serial port, two relays and four digital I/Os. It works in combination with our IPCP Pro xi Series control processors, which are securely configured with Global Configurator Professional or programmed with ControlScript®. This interface, as well as all Extron I/O Series Expansion Interfaces features the convenience of PoE and can be controlled, monitored, and accessed over your network. The IPL EXP 200 is a compact expansion solution housed in a durable 1U quarter rack enclosure and offers a broad variety of mounting options.
Copy TextCopied!An error occurred. Please try again later.
IPL EXP 200
Provide an Ethernet-enabled expansion interface for the purpose of remotely controlling and monitoring connected AV equipment and AV systems.
Ethernet-enabled expansion interface
Provide two RS-232 ports on captive screw connectors located on the back of the expansion interface that can be used for bidirectional control of AV system components
Provide one IR/Serial port on a captive screw connector located on the back of the expansion interface. This port shall allow the transmission of IR signals (using an IR emitter) or unidirectional RS-232 communications for control of AV system components.
Provide two low voltage relays on captive screw connectors located on the back of the expansion interface that can be used to control lighting, screens, or other device functions.
Provide four digital I/O’s on captive screw connectors that can be used to interface with devices such as sensors, switches, LEDs and relays.
Device shall have a female RJ-45 jack located on the back of the enclosure that supports 10/100 Base-T, half/full duplex with auto-detect for connection to a LAN or WAN and includes link and activity LED indicators located on the jack for troubleshooting network issues as well as supports PoE - Power over Ethernet, 802.3af
Device shall include a multi-function button and status LED located on the back of the enclosure that allows for the reset of the device or its communication properties at minimum
Device shall support the following protocols: ICMP (ping), IEEE 802.1X, IPv4, TCP/IP, UDP/IP, DHCP, DNS, HTTP (redirect), HTTPS, NTP, SFTP, SNMP, SSH
Supports a web-based AV resource management application that provides a means to manage, monitor, and control AV equipment
Device shall have at least 512 MB of nonvolatile memory
Provide front panel LED activity indicator for power status
Mounting requirements
Device shall be housed in a 1 RU, quarter rack width plastic enclosure
Device shall be rack mountable using an optional rack shelf
Device shall be able to mount securely on a variety of surfaces, including rack rails, tables, lecterns, projector poles, and table legs using an Extron ZipClip 200 mounting kit
Software requirements
The device may be configured or programmed using Extron’s Global Configurator Plus or Professional, or Global Scripter respectively.
Device drivers and modules can be obtained through Extron support resources and database.
Shall be configured or programmed by an Extron authorized user.
The device’s configuration and settings shall be managed using Extron’s Toolbelt software
Security Requirements
Device shall support SFTP and SSH for secure communication between the control processor and the IPL EXP I/O Series
Device shall support HTTPS for secure communication between the IPL EXP I/O Series and the embedded web pages
Device shall provide the option to modify administrator and user credentials
Device shall support security updates to maintain network health
Device shall require that a Secure Socket Layer (SSL) Certificate is installed to maintain system confidentiality and data integrity
Device shall support the installation of an owner furnished certificate with the following properties:
Certificates shall include x.509 support
Certificates shall include public / private key exchange
Certificates shall support PEM encoding
Extron shall furnish documentation that describes all supported network ports and services
Shall meet regulatory compliances
CE
c-UL
UL
C-Tick
FCC Class A
ICES
KCC
VCCI
RoHs
WEEE
Product Warranty
Shall provide at least 3 years parts and labor
Approved device shall be the Extron IPL EXP 200, part number 60-1908-01, no alternates or equals
IPL EXP 200
Provide an Ethernet-enabled expansion interface for the purpose of remotely controlling and monitoring connected AV equipment and AV systems.
Ethernet-enabled expansion interface
Provide two RS-232 ports on captive screw connectors located on the back of the expansion interface that can be used for bidirectional control of AV system components
Provide one IR/Serial port on a captive screw connector located on the back of the expansion interface. This port shall allow the transmission of IR signals (using an IR emitter) or unidirectional RS-232 communications for control of AV system components.
Provide two low voltage relays on captive screw connectors located on the back of the expansion interface that can be used to control lighting, screens, or other device functions.
Provide four digital I/O’s on captive screw connectors that can be used to interface with devices such as sensors, switches, LEDs and relays.
Device shall have a female RJ-45 jack located on the back of the enclosure that supports 10/100 Base-T, half/full duplex with auto-detect for connection to a LAN or WAN and includes link and activity LED indicators located on the jack for troubleshooting network issues as well as supports PoE - Power over Ethernet, 802.3af
Device shall include a multi-function button and status LED located on the back of the enclosure that allows for the reset of the device or its communication properties at minimum
Device shall support the following protocols: ICMP (ping), IEEE 802.1X, IPv4, TCP/IP, UDP/IP, DHCP, DNS, HTTP (redirect), HTTPS, NTP, SFTP, SNMP, SSH
Supports a web-based AV resource management application that provides a means to manage, monitor, and control AV equipment
Device shall have at least 512 MB of nonvolatile memory
Provide front panel LED activity indicator for power status
Mounting requirements
Device shall be housed in a 1 RU, quarter rack width plastic enclosure
Device shall be rack mountable using an optional rack shelf
Device shall be able to mount securely on a variety of surfaces, including rack rails, tables, lecterns, projector poles, and table legs using an Extron ZipClip 200 mounting kit
Software requirements
The device may be configured or programmed using Extron’s Global Configurator Plus or Professional, or Global Scripter respectively.
Device drivers and modules can be obtained through Extron support resources and database.
Shall be configured or programmed by an Extron authorized user.
The device’s configuration and settings shall be managed using Extron’s Toolbelt software
Security Requirements
Device shall support SFTP and SSH for secure communication between the control processor and the IPL EXP I/O Series
Device shall support HTTPS for secure communication between the IPL EXP I/O Series and the embedded web pages
Device shall provide the option to modify administrator and user credentials
Device shall support security updates to maintain network health
Device shall require that a Secure Socket Layer (SSL) Certificate is installed to maintain system confidentiality and data integrity
Device shall support the installation of an owner furnished certificate with the following properties:
Certificates shall include x.509 support
Certificates shall include public / private key exchange
Certificates shall support PEM encoding
Extron shall furnish documentation that describes all supported network ports and services
Shall meet regulatory compliances
CE
c-UL
UL
C-Tick
FCC Class A
ICES
KCC
VCCI
RoHs
WEEE
Product Warranty
Shall provide at least 3 years parts and labor
Approved device shall be the Extron IPL EXP 200, part number 60-1908-01, no alternates or equals
Add Item to Cart
Order Message Number
Part #
Note: Extron products using the Universal AC Outlet accept a number of different AC plug types. Before use, ensure that the device meets all regulatory requirements for your region and complies with all applicable local safety and electrical codes and standards.
Current Total:
IPL EXP 200 -
Annotation Graphics Processor
To view this page ensure that Adobe Flash Player version
11.0.0 or greater is installed and enabled.
Share this item via Email
IPL EXP 200
Control System I/O Expansion Interface
Please enter a valid e-mail address.
Thank you. Your email has been sent.
An error occurred while sending your e-mail. Please try again later.
Please upgrade your browser for the full Extron experience