IPL T CR48 |
|
Ethernet control interface |
Connectors | 1 RJ-45 female connector |
Data rate | 10/100Base-T, half/full duplex with autodetect |
Protocols | ARP, ICMP (ping), IP, TCP, UDP, DHCP, HTTP, SMTP, Telnet |
Default settings | Link speed and duplex level = autodetected IP address = 192.168.254.254 Subnet mask = 255.255.0.0 Gateway = 0.0.0.0 DHCP = off |
Web server | Up to 200 simultaneous sessions 7.25 MB nonvolatile user memory |
Program control | Extron Simple Instruction Set™ (SIS™) |
Global Viewer requirements | Microsoft® Internet Explorer® ver. 6 or higher |
|
Relay control interface |
Quantity/type | 8 normally open relays |
Relay control connectors | (2) 3.5 mm captive screw connectors, 8 pole |
Relay control contact rating | 24 V, 1 A |
|
Contact closure control interface |
Quantity/type | 4 contact closure inputs |
Contact input control connector | (1) 3.5 mm captive screw connector, 5 pole |
Contact closure (input only) | |
Input voltage range | 0 to 5 VDC, clamped at +5.1 V |
Input impedance | 10k ohms |
Threshold | 1.6 VDC |
Pin configurations | 1, 2, 3, 4 = inputs 1, 2, 3, 4; 5 = GND |
|
General |
Power | Supplied by an included external power supply |
External Power supply | 100 VAC to 240 VAC, 50-60 Hz, external; to 12 VDC, 1 A, regulated |
Power input requirements | 12 VDC, 0.5 A |
Ambient temperature/humidity | Storage: -40 to +158 °F (-40 to +70 °C) / 10% to 90%, noncondensing Operating: +32 to +122 °F (0 to +50 °C) / 10% to 90%, noncondensing |
Cooling | Convection, no vents |
Mounting | |
Rack mount | Yes, with optional 1U rack shelf |
Furniture mount | Yes, with optional under desk mounting kit |
Pole mount | Yes, with optional mini pole mount kit |
Enclosure type | Metal |
Enclosure dimensions | 1.7" H x 4.3" W x 3.0" D (1U high, quarter rack wide) (4.3 cm H x 10.9 cm W x 7.6 cm D) (Depth excludes connectors.) |
Product weight | 0.7 lbs (0.3 kg) |
Shipping weight | 2 lbs (1 kg) |
Vibration | ISTA 1A in carton (International Safe Transit Association) |
Regulatory compliance |
Safety | CE, c-UL, UL UL rated for use in plenum airspaces: meets UL 2043 for heat and smoke release, excluding the power supply; meets UL 60950 for safety. |
EMI/EMC | CE, C-tick, FCC Class A, ICES, VCCI |
Product warranty | 3 years parts and labor |
Everlast power supply warranty | 7 years parts and labor |
NOTE | All nominal levels are at ±10%. |
|
NOTE | Specifications are subject to change without notice. |
|
(8.0-080510-D11) |