MLC Plus 100 AAP

MediaLink Plus Controller with AAP Opening
Key Features
  • Manage, monitor, and control AV devices using a standard Ethernet network
  • Fully configurable using Global Configurator Plus or Global Configurator Professional
  • Two bidirectional RS-232 ports
  • Two relays for controlling room functions
  • One IR port for connecting up to two emitters
  • One digital input
The Extron MLC Plus 100 AAP
Model Version Description Part #
 MLC Plus 100 AAP White and Black Faceplates, 4-Gang AAP 60-1540-02

The MLC Plus 100 AAP is an easy-to-use Ethernet controller designed for handling common AV functions such as display on/off, input switching, volume control, and Ethernet control of AV devices. The faceplate hides the mounting screws and, combined with its rounded corners and beveled edges, gives the controller a refined, stylish appearance. Along with the six customizable and configurable buttons, the MLC Plus 100 AAP features a remote volume control port for Extron MPA Series and select XTRA™ Series amplifiers. Power over Ethernet - PoE allows the MLC Plus 100 AAP to receive power and communication over a single Ethernet cable. The MLC Plus 100 AAP mounts in a four-gang junction box, includes black and white faceplates, and has an opening for four single space AAPs.

The MLC Plus 100 AAP is configured using Extron Global Configurator Plus or Global Configurator Professional software. It also integrates seamlessly with Extron’s award-winning GlobalViewer® Enterprise software for complete AV resource monitoring, management, and control over a computer network. The MediaLink Plus family of controllers supports popular Web browsers and the Extron Control App.

Features

  • Manage, monitor, and control AV devices using a standard Ethernet network
  • Fully configurable using Global Configurator Plus or Global Configurator Professional
  • Two bidirectional RS-232 ports — Captive screw serial ports that can communicate with two RS-232 serially controlled devices.
  • Two relays for controlling room functions — Enables control of lighting, screen settings, and other device functions.
  • One IR port for connecting up to two emitters — For one-way control of external devices.
  • One digital input — Allows for a connection with a variety of devices, such as sensors, switches, and relays.
  • Remote volume control port for Extron MPA Series and select XTRA™ Series amplifiers
  • Volume control knob with LEDs for visual feedback — Control the volume of a device with RS-232, Ethernet, or IR; or remotely control the volume of Extron MPA and select XTRA™ Series amplifiers via the remote volume control port.
  • Power over Ethernet allows the controller to receive power and communication over a single Ethernet cable, eliminating the need for a local power supply
  • Supports Ethernet-controllable devices:
    • Up to 4 devices with GC Plus
    • Up to 8 devices with GC Pro
  • Removable captive screw connectors — Provides quick and easy connection to the controller for easy installation and troubleshooting.
  • Configurable buttons — Can be set up to control display power, input selection, volume, or any other IR/RS-232 command supported by the display.
  • Opening for up to four single space AAP - Architectural Adapter Plates — The MLC 100 AAP fits into a four-gang wall plate and includes an opening to accommodate up to four single space AAP - Architectural Adapter Plates. Blank AAPs are not included. The opening allows for integration with many Extron AAPs, including signal pass-through.
  • Dual color, field-labelable, backlit buttons —  Buttons illuminate red or white for ease of use in low-light environments. Pre-printed label sheets are included.
  • Removable button caps — Make it easy to label each button to clearly indicate its function. Labels can be quickly changed in the field and don't require programming or engraving.
  • Inactivity timer for display shutoff
  • Supports the Extron Control App
  • Extensive library of enhanced Extron Certified device drivers
  • Section 508 Compliant — Meets or exceeds U.S. accessibility standards for Electronic Information Technology. For more information about Extron's Commitment to Accessibility please see our Accessibility Page.
  • Flexible mounting options — Utilizing a standard electrical box or included mud ring, the MLC Plus 100 AAP can be installed virtually anywhere, including walls, lecterns, or tables.
  • Includes black and white four-gang, magnetically-attached faceplates
  • PoE injector or power supply sold separately
OPTIONAL ACCESSORIES
  AAP SuperPlate Series AV Connectivity Module for HDMI, DisplayPort, VGA, Stereo Audio, Network, and USB
  PI 115 Power Injector for XTP and Pro Series Control Systems
  SMB 110 Series Surface Mount Boxes for US-Gang Products
  IR Emitter and Shield Kits IR Emitter Kits for Extron Products With IR Output
COMPATIBLE SOFTWARE
  Global Configurator Plus and Global Configurator Professional Powerful Configuration Software for AV Control Systems
  Extron Control Control App for TouchLink, eBUS, Network Button Panels, and MediaLink
SIMILAR PRODUCTS
  MLC Plus 100 MediaLink Plus Controller
  MLC Plus 50 MediaLink Plus Controller
  MLC Plus 200 MediaLink Plus Controller
  MLC Plus 200 AAP MediaLink Plus Controller with AAP Opening

Specifications

MLC Plus 100 AAP
Memory
   SDRAM 512 MB
   Flash 512 MB
Software
   Configuration software Global Configurator® Plus and Professional
   Control apps Extron Control
   Resource management software GlobalViewer® Enterprise
   Utilities Toolbelt, embedded web page
Ethernet
   Network interface controllers (NICs) 1
   Connector 1 female RJ-45 connector
   Data rate 10/100/1000Base-T, half/full duplex with autodetect
   Protocols ARP, DHCP, DNS, HTTP (redirect), HTTPS, ICMP, IEEE 802.1X, NTP, SFTP, SMTP, SNMP, SSH, TCP/IP, UDP/IP
   Default settings Link speed and duplex level = autodetected
IP address = 192.168.254.250
Subnet mask = 255.255.255.0
Gateway = 0.0.0.0
DHCP = off
DNS: 127.0.0.1
Serial
   Quantity/type 2 bidirectional RS-232
   Connectors (2) 3.5 mm captive screw connectors, 3 pole
   Baud rate and protocol 300 to 115200 baud (9600 baud = default); 8 (default) or 7 data bits; 1 (default) or 2 stop bits;
no parity (default), even, or odd parity
    NOTE     These ports support software flow control. The default is no flow control.
   Pin configurations 
      Serial, 3-pole captive screw Pin 1 = Tx, 2 = Rx, 3 = Gnd
Digital input
   Quantity/type 1 digital input
   Connectors (1) 3.5 mm captive screw connector, 2 pole
   Digital input 
      Input voltage range 0 to 24 VDC, clamped at +30 VDC
      Input impedance 17.5k ohms
      Programmable pullup 1k ohms to +5 VDC
      Threshold low to high 2.8 VDC
      Threshold high to low 2.0 VDC
   Pin configurations 1 = digital input, 2 = Gnd
IR
   Quantity/type 1 TTL level (0 to 5 V) infrared (carrier and non-carrier) up to 300 kHz
   Connectors (1) 3.5 mm captive screw connector, 2-pole
   Pin configurations Pin 1 = signal, 2 = Gnd
   IR output carrier frequency 30 kHz to 300 kHz
Relay
   Quantity/type 2 normally open relays
   Relay control connectors (1) 3.5 mm captive screw connector, 3 pole
   Relay control contact rating 24 VDC, 1 A
Volume control
   Quantity/type 1 volume control (compatible with select Extron amplifiers)
   Connectors (1) 3.5 mm captive screw connector, 3 pole
   Pin configuration Pin 1 = ≤10 VDC reference voltage input, pin 2 = 0 to +10 VDC control voltage output, pin 3 = Gnd
   Control voltage output range 0 to +10 VDC (±0.2 volts), adjustable
General
   Power supply External (not included)
Input: 100-240 VAC, 50-60 Hz
Output: 12 VDC, 0.5 A, 6 watts
Or Power over Ethernet (PoE) (complies with PoE 802.3af, class 3), 48 VDC, 0.35 A, 16.8 watts
   Power consumption 
      Device  2.2 watts, 12 VDC
3.7 watts, 48 VDC (PoE)
      Device and power supply  3.0 watts, 100-240 VAC, 50-60 Hz
      Device and PoE injector 5.0 watts, 100-240 VAC, 50-60 Hz
   Ambient temperature/humidity Storage: -40 to +158 °F (-40 to +70 °C) / 10% to 90%, noncondensing
Operating: +32 to +122 °F (0 to +50 °C) / 10% to 90%, noncondensing
   Cooling Convection, no vents
   Thermal dissipation 
      Device  7.3 BTU/hr (using 12 VDC)
12.6 BTU/hr (using 48 VDC, PoE)
      Device and power supply  10.0 BTU/hr
      Device and PoE injector 17.1 BTU/hr
   Mounting 
      Rack mount No
      Furniture or wall mount Yes, in a standard US 4-gang electrical junction box or mud ring
   Enclosure type  Plastic faceplate and high-impact plastic rear enclosure
   Enclosure dimensions 
      Faceplate 4.50" H x 8.23" W x 0.30" D (114 mm H x 209 mm W x 7.6 mm D)
      Device  2.73" H* x 3.50" W x 2.16" D (69 mm H* x 89 mm W x 55 mm D)
(Depth excludes faceplate and buttons. Fits most 4 gang US boxes or mud rings. Allow at least 2.40" [61 nm] depth in the wall or furniture.)
       
   Product weight  0.8 lb (0.4 kg)
   Regulatory compliance CE, C-Tick, c-UL, FCC Class A, ICES, UL, VCCI class A
Complies with the appropriate requirements of RoHS, WEEE, and of Section 508 of the Rehabilitation Act (29 U.S.C. 794d).
   Product warranty 3 years parts and labor
    NOTE     All nominal levels are at ±10%.
    NOTE     Specifications are subject to change without notice.
(6013-D4)
Shipping Dimensions and Weights
    Part # Height Width Depth Weight
    60-1540-02 3.75" (9.5 cm) 5.5" (14.0 cm) 9.5" (24.1 cm) 1.65 lbs (0.75 kg)

Diagram

MLC Plus 100 AAP Diagram

Panel Drawing

MLC Plus 100 AAP Panel Drawing